Thermography has been use for more than 30 years but is still developing diagnostic modality. The technology has improved recently and thermography units are now affordable.

The human eye responds to visible light in the range of 0.4 to 0.75 microns, but the majority of the infrared temperature measurements range from 0.2 to 20 microns. A thermal imager is able to focus this energy on to a detector much like a regular camera, except it responds to the infrared radiation rather than visible light.

Thermographic cameras usually detect radiation in the long infrared range of the electromagnetic spectrum (roughly 9,000-14,000 nanometres or 9-14 μm) and produce image of that radiation, called thermograms. Infrared energy is emitted, transmitted and reflected by an object and the infrared cameras use algorithms to interpret the data to create an accurate interpretation of the operating temperature.

What the above paragraph says is that:

Incident Radiant Power = Emitted Radiant Power + Transmitted Radiant Power + Reflected Radiant Power

Two mutually exclusive approaches in thermography inspection:

  1. Passive: In which the features of interest are naturally at a higher or lower temperature than the background and no energy is introduced to the system being inspected.
  2. Active: In which an external stimulus source (i.e., optical flash lamps, heat lamps, hot or cold air guns, etc.) is required to produce a thermal contrast between the feature of interest and the background.

Infrared Thermography Techniques

There are mainly two classical active thermographic techniques based on optical excitation:

Pulsed Thermography

 In pulsed thermography (PT) the specimen surface is submitted to a short heat pulse using a high power source such as photographic flashes. The duration of the pulse may vary from a few milliseconds (2-15 ms) to several seconds depending on the thermo physical properties of both the specimen and the flaw.

Lock-In Thermography

In lock-in thermography (PT) the specimen’s surface is periodically illuminated by one or several modulated heating sources (Eg: halogen lamps) to inject thermal waves into the specimen. The periodic wave propagates by radiation through the air until it reaches the specimen surface where heat is produced and propagates through the material.